Psychological Science ›› 2018, Vol. ›› Issue (6): 1310-1317.

Previous Articles     Next Articles

The Influence of Reference Choice on Event-related Potentials Elicited by Emotional Pictures

  

  • Received:2017-01-30 Revised:2017-07-04 Online:2018-11-20 Published:2018-11-20
  • Contact: Yang-Ping Li

参考选择影响情绪加工相关的ERPs

李阳萍1,齐森青2,李欣颐3,张晥4,李亚丹1,陈熙彤2,侯雪珍5,胡卫平1   

  1. 1. 陕西师范大学
    2. 现代教学技术教育部重点实验室;陕西师范大学’
    3. 陕西师范大学,现代教学技术教育部重点实验室
    4. 陕西师范大学现代教学技术教育部重点实验室
    5. 陕西师范大学;现代教学技术教育部重点实验室
  • 通讯作者: 李阳萍

Abstract: Reference plays an important role in analyzing event-related potentials (ERP), because it can change ERP experiment results. Previous work concerning reference, however, has focused on the cognition area, but little is known about emotion area. To test the influence of reference choice on emotional processing, 24 participants performed a passive picture-viewing task involving positive, neutral, and negative pictures while EEG was recorded. Analyses mainly focused on P2 (160 to 230 ms), early posterior negativity (EPN, 220 to 300 ms), and late positive potential (LPP, 400 to 3000 ms) components. We compared three references (average reference; mean mastoids reference; reference electrode standardization technique, REST) on three aspects of these components. e.g., amplitudes, statistic power, and internal consistency. Furthermore, we tested the influence of reference choice on artifact rejection rates of ERP. Self-report behavioral results indicated the emotional pictures differed significantly in valence (ps < .01), and the arousal of emotional pictures were higher than neutral pictures (ps < .01). The ERP results showed that references have distinct influences on amplitudes and statistic power of ERP components as well as artifact rejection rates of ERP. Firstly, the temporal EPN amplitudes were higher under both REST and average reference than those under mean mastoids reference (ps < .05); however, there were quite opposite results for parietal LPP amplitudes (ps < .01). Secondly, the results of Monte Carlo simulations showed that the statistic power of the P2 amplitude difference between negative and neutral conditions increased under mean mastoids reference than those under both REST and average reference. However, the statistic power of EPN’s “positive bias” increased under REST and average reference than those under mean mastoids reference. Thirdly, the artifact rejection rates under mean mastoids reference were significantly higher than those under both average reference and REST (ps < .01). Lastly, the internal consistency of ERPs under three references were relatively good [P2 ( .76 - .87),EPN ( .87 - .96), and LPP ( .69 - .91)]. In summary, the influence of reference choice on amplitudes was moderated by the biggest active region of specific ERP components. Importantly, high likelihood of the P2 difference between negative and neutral conditions was detected under mean mastoids and average reference, while high likelihood of the EPN’s “positive bias” was detected under both REST and average reference. Additionally, a wider range of threshold to reject the artifact should be used under mean mastoids reference. Reference choice, however, has no effect on the reliability of P2, EPN, and LPP. In summary, in order to avoid distorting results and inappropriate conclusions, future ERP studies are supposed to select reference with caution according to specific components and related work.

Key words: reference, emotion, event-related potentials, amplitude, statistic power, artifact rejection rate

摘要: 研究采用情绪图片观看任务,考察双耳乳突参考、全脑平均参考和参考电极标准化技术(Reference electrode standardization technique, REST)对情绪相关ERP成分在波幅、统计功效、内部一致性方面的影响,以及参考选择对ERP伪迹剔除率的影响。结果显示,双耳乳突参考下颞区EPN的波幅显著小于REST和全脑平均参考下的结果,而在顶区LPP上表现出完全相反的结果。此外,双耳乳突和全脑平均参考下更可能检测到P2上负性和中性图片波幅间的差异,而REST和全脑平均参考下更可能检测到EPN的“正性偏向”效应。未来研究应结合以往文献和特定成分谨慎选择参考类型。

关键词: 参考 情绪 事件相关电位 波幅 统计功效 伪迹剔除率